Error Code
|
Status
|
Error Description
|
Possible Causes
|
Recommended Actions
|
Detection Conditions
|
Reset Procedure
|
|
E0.01
|
SHUTDOWN
|
Reverse phase connection
|
Incorrect phase sequence in the incoming power supply
|
Disconnect the power supply and interchange two of the three phase wires according to the electrical wiring diagram
|
Incorrect phase sequence detected within 3 seconds after power is supplied
|
Disconnect the power and reconnect the phases correctly
|
|
E0.01
|
SHUTDOWN
|
Phase loss
|
One phase of the incoming power supply is missing
|
Disconnect the power, check the power supply and tighten all power cable connections
|
Applicable to R and S versions as specified in the manual
|
Restore the power supply and electrical connections
|
|
E0.11
|
SHUTDOWN
|
High discharge air temperature
|
Oil separator element malfunction or end of service life
|
Inspect the oil separator element and replace it if necessary. Lubricate or replace related components as required
|
Oil separator outlet temperature reaches 110°C or higher
|
Press the RESET button
|
|
E0.24
|
ALARM
|
High discharge air temperature warning
|
Same possible causes as error E0.11
|
Perform the same inspections and corrective actions as for E0.11
|
Oil separator outlet temperature reaches 105°C or higher
|
Automatically resets
|
|
E0.12
|
SHUTDOWN
|
Abnormally high discharge air pressure
|
Oil separator element failure or contactor 52 malfunction
|
Inspect the oil separator element and replace it if necessary. Check and securely reconnect the contactor 52 wiring
|
Detected during compressor operation
|
Press the RESET button
|
|
E0.17
|
SHUTDOWN
|
Main motor overload
|
Motor overcurrent, abnormal power supply, excessive discharge pressure or clogged oil separator element (see E0.11)
|
Check the power supply, voltage and phase imbalance. Correct if necessary. Check and adjust the capacity control system if the discharge pressure setting exceeds the specified limit. Check the motor insulation resistance
|
Motor overcurrent detected
|
Press the RESET button
|
|
E0.53
|
SHUTDOWN
|
Cooling fan motor overload
|
Fan motor overcurrent, cooling system malfunction or clogged cooler air inlet/outlet
|
Check the power supply, voltage and phase imbalance. Clean the cooling fins of the oil cooler and aftercooler
|
Fan motor overcurrent detected
|
Press the RESET button
|
|
E0.18
|
SHUTDOWN
|
High discharge air temperature – Stage 1
|
Excessively high ambient temperature, low oil level, dirty or clogged oil cooler, or dirty or clogged oil filter
|
Improve machine room ventilation to reduce ambient temperature to approximately 40°C. Disconnect the power and ensure discharge pressure is 0 MPa before adding oil. Replace the oil cooler or oil filter if necessary
|
Stage 1 discharge air temperature exceeds 110°C
|
Press the RESET button
|
|
E0.23
|
ALARM
|
High discharge air temperature warning – Stage 1
|
Same possible causes as error E0.18
|
Perform the same inspections and corrective actions as for E0.18
|
Stage 1 discharge air temperature exceeds 105°C
|
Automatically resets
|
|
E0.31
|
SHUTDOWN
|
TH1 temperature sensor failure or disconnection
|
TH1 temperature sensor failure or disconnected wiring
|
Disconnect the power supply and inspect the TH1 sensor. Replace it if necessary. Reconnect and secure the TH1 wiring
|
Operating temperature below -30°C
|
Press the RESET button
|
|
E0.32
|
SHUTDOWN
|
TH2 temperature sensor failure or disconnection
|
TH2 temperature sensor failure or disconnected wiring
|
Disconnect the power supply and inspect the TH2 sensor. Replace it if necessary. Reconnect and secure the TH2 wiring
|
Operating temperature below -30°C
|
Press the RESET button
|
|
E0.34
|
SHUTDOWN
|
PS pressure sensor failure or disconnection
|
PS pressure sensor failure or disconnected wiring
|
Disconnect the power supply and inspect the PS sensor. Replace it if necessary. Reconnect and secure the PS wiring
|
Pressure reading is 0 MPa during operation
|
Press the RESET button
|
|
E0.47
|
SHUTDOWN
|
ROM board error (optional printed circuit board)
|
ROM failure on the printed circuit board
|
Disconnect and reconnect the power supply. If the problem persists, inspect the printed circuit board
|
Error remains after restarting the compressor
|
Disconnect and reconnect the power. The controller cannot be reused if the fault persists
|
|
E0.48
|
SHUTDOWN
|
RAM board error (optional printed circuit board)
|
RAM failure on the printed circuit board
|
Disconnect and reconnect the power supply. If the problem persists, inspect the printed circuit board
|
Error remains after restarting the compressor
|
Disconnect and reconnect the power. The controller cannot be reused if the fault persists
|
|
E0.51
|
SHUTDOWN
|
Contactor 52 feedback error
|
Contactor 52 malfunction or incorrect feedback signal
|
Disconnect the power supply. Inspect contactor 52 and securely reconnect its wiring. Replace the contactor if necessary
|
Detected during compressor operation
|
Press the RESET button
|
|
E0.57
|
SHUTDOWN
|
Cooling fan inverter abnormality
|
Cooling fan inverter malfunction
|
Inspect the fan inverter, cooling fan and related wiring according to the technical manual
|
Cooling fan inverter fault detected
|
Press the RESET button
|
|
E0.66
|
SHUTDOWN
|
Cooling fan inverter communication error
|
Communication failure between the controller and control circuit board
|
Inspect communication cables, connectors and wiring connections
|
Communication retry limit exceeded
|
Press the RESET button
|
|
E0.21
|
ALARM
|
Clogged air intake filter
|
Dust accumulation or blockage in the air intake filter
|
Clean or replace the air intake filter
|
Filter differential pressure reaches 7.47 kPa
|
Press the RESET button
|
|
E0.22
|
ALARM
|
Low oil level (optional)
|
Insufficient oil level
|
Check the oil level and refill with the specified compressor lubricant if necessary
|
Detected by the optional oil level sensor
|
Follow the reset procedure specified for the compressor model
|
|
U100
|
ALARM
|
Excessive suction valve loading/unloading cycles
|
The suction throttle valve has reached a total of 1,000,000 loading/unloading cycles
|
Replace the consumable components of the suction throttle valve
|
1,000,000 operating cycles reached
|
Hold the REMOTE button and press SELECT for more than 7 seconds
|