Hitachi HISCREW Air Compressor Error Codes

Hitachi HISCREW Air Compressor Error Codes

(Nov 11 2026 - Views: 3)

Hitachi HISCREW air compressors are widely used in industrial compressed air systems. During operation, the compressor's control system monitors electrical components, motor conditions, discharge temperature, oil circulation, air pressure and other operating parameters.

When an abnormal condition occurs, the controller displays an alarm or shutdown error code to help operators and maintenance technicians identify the problem.

This guide provides a detailed reference table of Hitachi HISCREW air compressor error codes, including error descriptions, possible causes, troubleshooting procedures, detection conditions and reset instructions.

1. Hitachi HISCREW Air Compressor Error Code List

Error Code

Status

Error Description

Possible Causes

Recommended Actions

Detection Conditions

Reset Procedure

E0.01

SHUTDOWN

Reverse phase connection

Incorrect phase sequence in the incoming power supply

Disconnect the power supply and interchange two of the three phase wires according to the electrical wiring diagram

Incorrect phase sequence detected within 3 seconds after power is supplied

Disconnect the power and reconnect the phases correctly

E0.01

SHUTDOWN

Phase loss

One phase of the incoming power supply is missing

Disconnect the power, check the power supply and tighten all power cable connections

Applicable to R and S versions as specified in the manual

Restore the power supply and electrical connections

E0.11

SHUTDOWN

High discharge air temperature

Oil separator element malfunction or end of service life

Inspect the oil separator element and replace it if necessary. Lubricate or replace related components as required

Oil separator outlet temperature reaches 110°C or higher

Press the RESET button

E0.24

ALARM

High discharge air temperature warning

Same possible causes as error E0.11

Perform the same inspections and corrective actions as for E0.11

Oil separator outlet temperature reaches 105°C or higher

Automatically resets

E0.12

SHUTDOWN

Abnormally high discharge air pressure

Oil separator element failure or contactor 52 malfunction

Inspect the oil separator element and replace it if necessary. Check and securely reconnect the contactor 52 wiring

Detected during compressor operation

Press the RESET button

E0.17

SHUTDOWN

Main motor overload

Motor overcurrent, abnormal power supply, excessive discharge pressure or clogged oil separator element (see E0.11)

Check the power supply, voltage and phase imbalance. Correct if necessary. Check and adjust the capacity control system if the discharge pressure setting exceeds the specified limit. Check the motor insulation resistance

Motor overcurrent detected

Press the RESET button

E0.53

SHUTDOWN

Cooling fan motor overload

Fan motor overcurrent, cooling system malfunction or clogged cooler air inlet/outlet

Check the power supply, voltage and phase imbalance. Clean the cooling fins of the oil cooler and aftercooler

Fan motor overcurrent detected

Press the RESET button

E0.18

SHUTDOWN

High discharge air temperature – Stage 1

Excessively high ambient temperature, low oil level, dirty or clogged oil cooler, or dirty or clogged oil filter

Improve machine room ventilation to reduce ambient temperature to approximately 40°C. Disconnect the power and ensure discharge pressure is 0 MPa before adding oil. Replace the oil cooler or oil filter if necessary

Stage 1 discharge air temperature exceeds 110°C

Press the RESET button

E0.23

ALARM

High discharge air temperature warning – Stage 1

Same possible causes as error E0.18

Perform the same inspections and corrective actions as for E0.18

Stage 1 discharge air temperature exceeds 105°C

Automatically resets

E0.31

SHUTDOWN

TH1 temperature sensor failure or disconnection

TH1 temperature sensor failure or disconnected wiring

Disconnect the power supply and inspect the TH1 sensor. Replace it if necessary. Reconnect and secure the TH1 wiring

Operating temperature below -30°C

Press the RESET button

E0.32

SHUTDOWN

TH2 temperature sensor failure or disconnection

TH2 temperature sensor failure or disconnected wiring

Disconnect the power supply and inspect the TH2 sensor. Replace it if necessary. Reconnect and secure the TH2 wiring

Operating temperature below -30°C

Press the RESET button

E0.34

SHUTDOWN

PS pressure sensor failure or disconnection

PS pressure sensor failure or disconnected wiring

Disconnect the power supply and inspect the PS sensor. Replace it if necessary. Reconnect and secure the PS wiring

Pressure reading is 0 MPa during operation

Press the RESET button

E0.47

SHUTDOWN

ROM board error (optional printed circuit board)

ROM failure on the printed circuit board

Disconnect and reconnect the power supply. If the problem persists, inspect the printed circuit board

Error remains after restarting the compressor

Disconnect and reconnect the power. The controller cannot be reused if the fault persists

E0.48

SHUTDOWN

RAM board error (optional printed circuit board)

RAM failure on the printed circuit board

Disconnect and reconnect the power supply. If the problem persists, inspect the printed circuit board

Error remains after restarting the compressor

Disconnect and reconnect the power. The controller cannot be reused if the fault persists

E0.51

SHUTDOWN

Contactor 52 feedback error

Contactor 52 malfunction or incorrect feedback signal

Disconnect the power supply. Inspect contactor 52 and securely reconnect its wiring. Replace the contactor if necessary

Detected during compressor operation

Press the RESET button

E0.57

SHUTDOWN

Cooling fan inverter abnormality

Cooling fan inverter malfunction

Inspect the fan inverter, cooling fan and related wiring according to the technical manual

Cooling fan inverter fault detected

Press the RESET button

E0.66

SHUTDOWN

Cooling fan inverter communication error

Communication failure between the controller and control circuit board

Inspect communication cables, connectors and wiring connections

Communication retry limit exceeded

Press the RESET button

E0.21

ALARM

Clogged air intake filter

Dust accumulation or blockage in the air intake filter

Clean or replace the air intake filter

Filter differential pressure reaches 7.47 kPa

Press the RESET button

E0.22

ALARM

Low oil level (optional)

Insufficient oil level

Check the oil level and refill with the specified compressor lubricant if necessary

Detected by the optional oil level sensor

Follow the reset procedure specified for the compressor model

U100

ALARM

Excessive suction valve loading/unloading cycles

The suction throttle valve has reached a total of 1,000,000 loading/unloading cycles

Replace the consumable components of the suction throttle valve

1,000,000 operating cycles reached

Hold the REMOTE button and press SELECT for more than 7 seconds

2. Important Hitachi HISCREW Error Codes Explained

E0.17 – Main Motor Overload

Error E0.17 indicates that the main compressor motor has experienced an overcurrent condition.

Possible causes:

  • Low or unstable incoming voltage.
  • Voltage imbalance between the three phases.
  • Excessive compressor discharge pressure.
  • Clogged oil separator element.
  • Motor insulation deterioration.
  • Mechanical overload of the compressor airend.

Troubleshooting procedures:

  1. Measure the incoming three-phase voltage.
  2. Measure the current on all three motor phases using a clamp meter.
  3. Compare the measured current with the motor nameplate rating.
  4. Inspect the motor protection relay and electrical connections.
  5. Check the discharge pressure and oil separator differential pressure.
  6. Perform an insulation resistance test using a megohmmeter (Megger), following the manufacturer's testing requirements.

Do not assume that the motor is defective based on error E0.17 alone. Both electrical and mechanical conditions must be checked.

E0.18 – High Discharge Air Temperature

This error indicates that the Stage 1 discharge air temperature has exceeded the specified shutdown limit.

Possible causes:

  • Low compressor oil level.
  • Dirty or clogged oil cooler.
  • Clogged oil filter.
  • Insufficient cooling airflow.
  • High ambient temperature in the compressor room.

Troubleshooting procedures:

  1. Check the compressor oil level.
  2. Inspect the oil condition and oil circulation system.
  3. Clean the oil cooler and aftercooler.
  4. Inspect the cooling fan and airflow.
  5. Check the oil filter and replace it if necessary.
  6. Improve machine room ventilation.

E0.11 – High Discharge Air Temperature

Error E0.11 indicates that the oil separator outlet temperature has reached the shutdown threshold.

Possible causes:

  • Oil separator element malfunction.
  • Deteriorated oil separator components.
  • Insufficient oil circulation.
  • Cooling system problems.

Recommended actions:

  • Inspect the oil separator element.
  • Check the oil circulation and return lines.
  • Inspect the cooling system.
  • Replace defective components according to the Hitachi maintenance manual.

E0.34 – Pressure Sensor Failure

This error indicates a problem with the PS pressure sensor or its electrical connection.

Troubleshooting procedures:

  1. Inspect the pressure sensor wiring.
  2. Check the electrical connectors.
  3. Compare the controller pressure reading with an independent calibrated pressure gauge.
  4. Inspect the sensor signal according to the wiring diagram.
  5. Replace the sensor only after confirming that it is defective.

E0.21 – Clogged Air Intake Filter

This alarm indicates that the air intake filter differential pressure has reached the specified limit.

Recommended actions:

  • Inspect the air intake filter.
  • Clean the filter if it is reusable and permitted by the manufacturer.
  • Replace the filter if it is damaged or excessively contaminated.
  • Check the filter differential pressure after maintenance.

3. Important Safety Precautions Before Resetting a Hitachi Air Compressor

Before resetting a Hitachi HISCREW air compressor, maintenance technicians should follow these precautions:

  1. Record the displayed error code before resetting the controller.
  2. Identify and eliminate the root cause of the fault.
  3. Disconnect and isolate the electrical supply before carrying out electrical inspections.
  4. Ensure that the compressor has been fully depressurized before opening any pressurized components.
  5. Check that all safety conditions are satisfied before restarting the machine.
  6. Follow the reset procedure specified in the relevant Hitachi instruction manual.
  7. Never repeatedly reset the compressor without identifying and correcting the underlying problem.

For high-temperature, motor overload and mechanical faults, a thorough inspection is essential before restarting the compressor.

4. Hitachi Air Compressor Maintenance and Repair Services – NHAT HUY

NHAT HUY provides industrial compressed air solutions, maintenance and repair services for Hitachi air compressors in Vietnam.

Our technical services include:

  • Hitachi screw air compressor troubleshooting and repair.
  • Electrical control system inspection and repair.
  • Inverter and variable frequency drive (VFD) troubleshooting.
  • Oil separator, oil filter and air filter replacement.
  • Preventive maintenance and periodic servicing.
  • Hitachi compressor airend overhaul.
  • Industrial motor inspection and overhaul.
  • Genuine Hitachi compressor spare parts supply.
  • Compressed air system design and installation.
  • Energy efficiency assessment and optimization.

If your Hitachi air compressor displays an alarm or shutdown error code, contact NHAT HUY for technical assistance.

Tags: Hitachi HISCREW Air Compressor Error Codes